Rubber plastic ozone aging test chamber is mainly adopted for rubber products testing such as vulcanized rubber, thermoplastic rubber, cable insulation sheathing products, intermittent static tensile dynamic tensile deformation, or deformation under dynamic stretching and static stretching alternating, confined to light with constant ozone concentration in the air and constant temperature chamber exposed to detection, scheduled on the specimen occurred from the specimen surface cracking or other properties of the degree of change, resistance to ozone in order to assess the rubber aging properties.

Standard Features

Item Specification
Internal dimension 450W*450D*500Hmm (100L)
Temperature range RT+10~ 60℃ (suggest to use 40℃±2℃)
Temperature Fluctuation ±1℃
Ozone concentration 50~1000 pphm, adjustable (suggest to use 50pphm)
Ozone concentration deviation ±10%
Sample holder rotation 360 degree rotation
Sample holder 2pcs removable sample tray, SUS#304 stainless steel
Temperature controller Programmable touch screen controller
Ozone concentration analysis Concentration analysis meter
Ozone generator High pressure silence discharge type
Protection system Leakage, short circuit, over temperature, over heat

Chamber Structure And Features

1, Internal material is imported high quality mirror stainless steel plate.

2, External material adopts stainless steel with paint spray.

3, Insulation material: high-density glass fiber

4, Use long axial fan motor and high and low temperature resistant aluminum alloy wing type wind turbines to force vertical air circulation.

5, Chamber door adopts double layer high and low temperature resistant silicone seal ensure the airtight test area.

6, Chamber bottom has high quality universal wheel and fixed foot cup.

7, Observation window uses multilayer hollow tempered glass.

8, Exhaust system: exhaust the high concentration ozone from the test chamber to avoid to poison.

9, Fixture: Built-in 360 degree rotation sample holder, including 3 sets static tensile fixture and 3 sets dynamic tensile fixture.

Programmable Control System

1, With imported micro-computer LCD controller to control the temperature.

2, PID control

3, With auto calculation function to reduce the setting inconvenience.

4, Heater: fin type radiator pipe nickel-chromium alloy u-shaped heater, auto calculate with high accuracy PID + SSR control

5, Temperature measurement: SUS#304, PT 100

Standard Configuration

1, Power line x 1pc

2, Sample holder x 1set

3, Fuse x 1set

4, Static and Dynamic fixtures x 3sets

5, Controller operation manual x 1set

6, Machine operation manual x 1set