Product Description
This calibration device is designed in accordance with ASTM D5207-03 and related IEC, UL, GB standards for measuring flame temperatures in combustion test equipment.

Calibration Procedure:
Position the copper block 10±1mm above the needle flame burner.
Ignite the flame; the time for the copper block temperature to rise from 100°C±2°C to 700°C±3°C must be 44±2 seconds to validate the flame for testing.
Perform three measurements, allowing the copper block to cool naturally to <50°C between tests.

Product Specifications

Model 6014-HD
Thermocouple Armored K-type (NiCr/NiAl) fine-wire thermocouple with a 0.5mm diameter sheath
Timer Adjustable range: 0.01–99.99 seconds
Copper Block Specifications
Diameter Ø5.50±0.01mm
Length 8.80±0.02mm
Bevel Angle 45±0.5°
Mass (Pre-drilling) 1.76g±0.01g
Material High-conductivity electrolytic copper
Surface Finish Fully polished