Hot-Wire Ignition Tester

  1. Home
  2. /
  3. Altra macchina di prova
  4. /Hot-Wire Ignition Tester

Hot-Wire Ignition Tester

Description

Product Description
This tester simulates fire hazards as specified in IEC 60695-2-20, UL 60950, IEC 60950-1999, and ASTM D3874-1997. It employs a heating wire of specific dimensions (0.5mm × 250mm) and material (Ni80/Cr20), pre-annealed at a defined power (0.26W/mm) and duration (8–12 seconds).
The wire is wound in five full turns around the sample at a 6mm pitch, then tested at the same power (0.26W/mm) until ignition or for up to 120 seconds. The test evaluates fire risks based on ignition occurrence or time to ignition.

Compliance Standards:

GB/T 4943-2022, IEC 60950:1999, IEC 60695-2-20:2021, UL 60950, ASTM D3874-1997

Product Specifications

Model 6004-HD
Chamber Volume ≥0.5 m³, with a glass observation door.
Heating Wire Specification Diameter: Ø0.5mm, length: 250mm±5mm, material: nickel-chromium alloy (80% Ni, 20% Cr, iron-free), cold resistance: ~5.28 Ω/m
Annealing Stand Spacing 250mm
Sample Stand Spacing 70mm
Sample Stand Height 60mm
Annealing Time 8–12 seconds (adjustable range: 1–999.9 seconds, digital display)
Annealing Power 0.26W/mm ±4%, digitally adjustable and displayed
Test Duration 120 seconds (adjustable range: 1–999.9 seconds, digital display)
Test Power 0.26W/mm ±4%, digitally adjustable and displayed
Sample Dimensions 130mm (length) × 13mm (width)
Key Features Black interior background, integrated ventilation and lighting, digital display for time and power, ensuring easy observation, recording, and reliable operation.
Power Supply AC 220V, 50Hz.