HD-E808-200 Salt Spray Chamber
EQUIPMENT DETAILS
Control panel Inner Chamber
GENERL SPECIFICATIONS
Packaging Dimensions: (WxDxH) 2900*1450*1700mm
Power supply source: single-phase, 220V±10%, 50Hz (can be appointed)
Gross Weight: 350kg
HS Code: 8479899990
STANDARD PARAMETERS
Model | HD-E808-200 |
Internal Size (W*D*H) | 2000*1000*600mm |
External Size (W*D*H) | 2700*1250*1500mm |
Equipment Material | P.V.C rigid plastic plate, thickness 8mm |
Sample tray | Diameter 10mm glass fiber rod, anti-rust V-shape plastic steel to make sure sample in 15~30 degree inclined |
Temperature Range | Room temperature ~ 55℃ |
Temperature Fluctuations | ≤±0.5℃ |
Temperature Uniformity | ≤±2℃ |
Temperature Precision | ±1℃ |
Spraying method | Continuous and Periodic spray type |
Test Chamber Temperature | Salt Spray Method (NSS ACSS)35±1℃ |
Saturated air Barrel Temperature | Salt Spray Method (NSS ACSS)47±1℃ |
Brine Temperature | 35℃±1℃ |
Spray Quantity | 1.0~2.0 ml / 80cm2 / hr |
PH value | Salt Spray Method (NSS ACSS6.5~7.2) |
Lab Volume | 1200L |
Brine Tank Capacity | 40L |
Multiple Safety Protection Devices | Current discharge protection, over pressure protection, over temperature protection, over load fuse protection |
Accessories | Testing Salt / Measuring tank / Spray Nozzle x 1 set |
Air source | Air pump (provided by buyer) |
Test criteria | ASTM B117-08, ISO 9227... |
PRODUCT FEATURES
1. Durable hard 5 mm PVC construction, anti-corrosion and easy to clean.
2. Reservoirs with mixing system on stand.
3. Separate heating system apart from salt testing chamber to ensure accurate result and protect circuit.
4. Exposure zone lined with corrosion-resistant PVC sheets.
5. Clear cover allows viewing of test conditions.
6. Peaked cover prevents dripping of condensation onto samples.
7. Water seal and water level protection system.
8. Heated humidifying tower with air relief valve, adjustable tower tip to orient salt fog.
9. Automatic DI water fills to humidifying tower.
10. Digital temperature control.
11. Integral over-protection on heaters.
12. Low water cut-off protection on humidifying tower.
EQUIPMENT IMAGES
Spray nozzle