Battery Short Circuit Test Chamber

  1. Home
  2. /
  3. Battery Test Equipment
  4. /Battery Short Circuit Test Chamber

Battery Short Circuit Test Chamber

Description

Product Description

Temperature control battery short circuit test chamber is used to test whether the battery will explode and catch fire when a certain resistance is short-circuited under high temperature, and at the same time display the maximum short-circuit current through the relevant instrument.

During the test, the surface temperature of the sample should not exceed 170°C. After the test is completed, the sample shall be a qualified product without decomposition, cracking and fire phenomenon.

Test requirements: IEC 62133-2017 UL 1642 UN 38.3

Product Specifications
Our Experts Can Help You Find the Perfect Battery Short Circuit Test Chamber

Model HD-H201
Inner box size 500x500x500mm (width x depth x height);
Equipment dimensions 700x800x1530mm (width x depth x height);
Internal material SUS201 stainless steel plate, thickness 1.2mm, with Teflon affixed;
External material 1.5mm thick cold-rolled steel plate with paint treatment;
Observation window The size is 250x250mm two-layer tempered glass, the transparent window is equipped with stainless steel mesh;
Smoke outlet 100mm in diameter, located at the back of the box;
Pressure relief port The size of the opening is 200x200mm, located on the back side of the box. When the sample explodes, the pressure relief port will pop open to relieve the pressure;
Box door The single door opens to the left, the box door is equipped with a safety limit switch, and the side is equipped with an explosion-proof chain. The device can be operated only when the box door is closed to ensure the safety of personnel;
Test hole There are 2 test holes with a diameter of 50mm on the left side of the device, which are convenient for putting in the collection lines of temperature, voltage, current, etc.;
Lighting device It is convenient to observe the state of the tested sample;
Temperature collection range RT-1000℃;
Temperature acquisition channel 1 channel;
Temperature display accuracy ±0.5℃;
Voltage acquisition range 0-100V;
Voltage acquisition channel 1 channel;
Voltage display accuracy ±0.5%;
Maximum short-circuit current 1000A;
Current acquisition channel 1 channel;
Current display accuracy ±0.5%;
The internal resistance of the device loop 80±20mΩ;
Equipment movement There are four universal casters at the bottom of the equipment, which can be moved freely;
Control method PLC touch screen control;
Equipment weight 85Kg
Power supply AC220V;50Hz/60Hz