8100-HD HVDC Power-Supply Module

  1. Startseite
  2. /
  3. Batterieprüfgeräte
  4. /8100-HD HVDC Power-Supply Module

8100-HD HVDC Power-Supply Module

Beschreibung

Main Features:

  • 700V⇋5V Direct Conversion
  • Currentrange: 60A~450A
  • Flexible channel configuration based on requirements, supporting quick plug-and-playinstallation/replacement
  • Standardized dimensions for single-channel module series: 185 mm* 155 mm*42 mm
  • 24-bit high-frequency ADC sampling with analog-digital hybrid filtering, deliveringhigher measurement accuracy
  • Smooth transition between charge and discharge, seamless constant current toconstant voltage conversion with faster and smoother response
  • Operatingtemperature:0° C~50° C

 

Hauptparameter:

 

Operating Mode Standby,stop,constant-current(CC)charging/discharging,constant-voltage(CV)charging/discharging,constant-power(CP)charging/discharging,constant-current/constant-voltage(CC/CV)charging/discharging
Cut of Conditions

 

Voltage,current,time,capacity
 

Forward Operation

(Charging)

Input voltage (high- voltage side) 650Vdc~720Vdc

 

Input reverse polarity protection Provided
Output voltage(low-voltage side) 0Vdc~5Vdc(Adjustable)
Voltage accuracy(cell side) ±0.02%FS@25±5℃
Charging current 450mA~1200000mA
Current accuracy(cell side) ±0.04%FS@25±5℃
Charging efficiency Peak efficiency>92%
Reverse Operation

(Discharging)

 

Input voltage(low-voltage side) 0.5Vdc~5Vdc,Terminal Voltage
Voltage accuracy(cell side) ±0.02%FS@25±5℃
Current range 120mA~450000mA
Current accuracy(cell side) ±0.04%FS@25±5℃
Output voltage(high-voltage side) 640Vdc~750Vdc
Maximum output current 1200000mA
Discharging efficiency Peak efficiency >90%
Functionality and

Parameter Requirements

 

Response

 

Current response time 10%~90%FS:<10ms
Charge/discharge current switching time 90%~+90%FS:<20ms
Current overshoot:<5%FS 0.5m(with0.5mpowercablelength)
Ripple:<1%FS
Protection

 

 

Over-voltage protection,under-voltage protection,over-current protection,

Output short-circuit protection,over-temperature protection,battery reverse-connection protection,

Communication loss protection,sampling abnormality protection,power-side fuse protection

Negative voltage acquisition Capable of directly acquiring true negative voltage
Auxiliary voltage Provides auxiliary voltage sampling with accuracy less than 2mV
Data reporting Process step number and timestamp,battery voltage,terminal voltage,Auxiliary voltage,charge/discharge current,capacity,energy,operating status
Auflösung (Voltage setting resolution):1mV

(Voltage display resolution):0.1mV

(Current setting resolution):1mA

(Current display resolution):0.1mA

 

ESD protection (Contact discharge)≥6KV,

(Air discharge)≥10KV

 

Communication CAN2.0,communication baud rate 125K/500K
Cooling  

Forced air cooling with intelligent fan speed control

 

 

WhatsApp