Description du produit
1. Applicable for fire resistance tests on products such as doors and roller shutters installed in vertical partition openings, to determine integrity and insulation failure times.
2. Suitable for fire resistance tests on fire doors (GB12955), glazed components (GB12513), fire shutters (GB14102), and fire-resistant glass (GB15763.1).
3. With over 20 years of technical expertise, the vertical furnace offers improved accuracy and reliable stability.
4. The furnace heating and pressure conditions comply with GB/T 9978.1 standard requirements.
Normes de conformité :
GB/T 9978.1-2008 Fire Resistance Tests — General Requirements
GB/T 12955-2008 Fire Door Test Standards
GB/T 7633-2008 Fire Resistance of Doors and Shutters
GB 16809-2008 Fire Window Standards
GB/T 12513-2006 Glazed Components Fire Resistance Test
GB/T 8478 Aluminum Alloy Door and Window Standards
GB 15763.1-2009 Fire-Resistant Safety Glass
Spécifications du produit
| Modèle | 6045-HD |
| Service Life | ≥15–20 years |
| Internal Temperature | Up to 1300°C |
| Insulation Material | Zircon-containing refractory cotton (1600°C rating) |
| Furnace Dimensions | 3000mm (W) × 3000mm (H) × 1500mm (D) |
| Frame Material | Q235-A structural steel |
| Refractory Brick | Max 1750°C; Long-term 1600°C |
| Protective Coating | Three-layer anti-corrosion coating |
| Foundation Load | ≥750 kg/m² |
| Required Space | ≥150 m², ceiling height ≥5.5 m |
Adresse : Chambre 101, Bâtiment 3, N°1, Route Dongwei 1ère, Rue Wanjiang, Dongguan, Guangdong.
Téléphone : +86 138 2726 8067