Sanitary Tapware Hot&Cold Mixing Valve Cartridge life test machine is designed to meet the ASMEA112.18.1-2005/CSAB125.1-05/GB18145 and EN817 test conditions for hot and cold mixing spool life test.

| Model | 5075-HD |
| Test Sample | 2 Rising, 2 Side stations |
| Upper and Lower Adjustable Mounting Blocks | |
| Cold and hot water unit | 1 set of 500L |
| Sıcaklık aralığı | 5℃~90℃ can be set. Hot and cold water inlet temperature can be selected individually |
| Operating hours | 99H59M59S can be set. Working time can be set without stopping, with pause button |
| Additional functions for the unit | Cleaning system and drainage system (increase drainage motor) |
| Test head | Can adjust the distance back and forth |
| Water return | Suction pump |
| Control product movement | Individually control the up and down, left and right action of each product |
| Test hızı | 0-30 times/min can be set |
| Counting function | 0-99999999 can be set |
| Sample angle On | Ayarlanabilir |
| Kontrol modu | PLC software |
| Operation mode Power Supply | 7" color touch screen |
| Güç | 380V 50HZ, 24KW |
| Air Supply | 6kg |
| Malzeme | SUS304 stainless steel |
Adres: Guangdong Dongguan, Wanjiang Sokağı, Dongwei 1. Cadde No:1, Bina 3, Oda 101, Dongguan, Guangdong.
Telefon: +86 138 2726 8067
E-posta: haidaequipment@qc-test.com