Flat Plate Thermofluidometer Method

  1. Home
  2. /
  3. Thermal Conductivity Tester
  4. /Flat Plate Thermofluidometer Method

Flat Plate Thermofluidometer Method

Description

Product Description

Thermal Conductivity Tester adopts the internationally popular method of heat flow meter to detect thermal conductivity and thermal resistance, with computer to realize fully automatic detection and generation of experimental report.
The instrument adopts to add stable hot surface temperature on one side of the specimen, the heat is transferred to the cold surface through the specimen, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance.
Adopting imported sensors and computer technology, it is characterized by good measurement accuracy, high reliability and good repeatability. Especially suitable for low thermal conductivity measurement (accurate to 0.1mw). It can be used for testing plastics, rubber, thermal insulation materials, aerogel panels, vacuum glass, etc. It is widely used in colleges and universities, scientific research institutes, quality inspection, factories and mines.

Product Specifications

Model 60086-HD
Thermal conductivity range 0.0001 ~ 1W / mk, can be measured accurately to 0.1mw / mk, 0.001 ~ 300W / mk. computer automatically switch range
Measuring accuracy 1%
Specimen size 50*50 ~ 150*150, 150*150 ~ 300*300(mm) optional (standard configuration), the thickness is not greater than 50mm.
Sample state Can test solid material, powder material
Measuring time 15~20 min
Hot surface temperature range RT~ 99.9 ℃ (standard configuration), RT ~ 299.9 ℃, RT ~ 499.9 ℃ optional
Hot surface temperature control Plate heater, bi-directional SCR control, temperature control accuracy 0.1℃
Cold surface temperature range 0 ~ 99.9 ℃ (standard configuration), -10 ~ 99.9 ℃, according to user requirements to determine the lower temperature
Cold surface temperature control Water-cooled to ensure the stability of the cold surface temperature (precision thermostatic water tank, temperature adjustable), temperature control accuracy of 0.1 ℃
Specimen clamping pressure range 0 ~ 1000N, resolution 0.1N
Sample thickness range Measure automatically, 0 ~ 50mm, resolution 1um
Heat flow meter Imported original heat flow meter
Data storage Computerized automatic testing and storage printing and storage of experimental data
Machine dimension (L*W*H)550*450*1500mm
Machine weight Approx. 100KG
Water bath dimension (L*W*H)300*350*530mm
Water bath weight Approx. 35KG
Power 1∮ AC 220V 1KW
Standards GB/T10295-2008, ASTM E1530, ASTM C518-04, ISO 8301, DIN EN 12664